Intraocular lenses for humans and animals, IOL delivery system, eye prostheses.
CrystalView® LM-B
Intraocular lens
with injector and cartridge
CrystalView® LM-S
Intraocular lens
with injector and cartridge
CrystalView® LM-M105
Intraocular lens
with injector and cartridge
CrystalView® LM-Q110
Intraocular lens
with injector and cartridge
CrystalView® LM-X105
Intraocular lens
with injector and cartridge
CrystalView® LM-H107
Intraocular lens
with injector and cartridge
ZooView® Q110
Hydrophilic intraocular lenses
for dogs and cats
IOL-CHALLY®
Intraocular lens
IOL-S-CHALLY®
Intraocular lens
IOL-CHALLY® T2
Intraocular lens
IOL-CHALLY® T4
Intraocular lens
Eye prostheses polymeric
Polymeric individual single-and double-walled prostheses
CrystalView® LM-B
Intraocular lens with injector and cartridge

LM-B575S LM-B60S LM-B60M LM-B625M
Optics diameter
5.75 mm 6.00 mm 6.00 mm 6.25 mm
Haptic diameter
12.00 mm 12.00 mm 12.50 mm 12.50 mm
Material
Hydrophilic acrylic
Lens type
Posterior chamber
Diopter series
-15.0 D to -0.5 D in 0.5D increments from +0.5 D to +45.0 D in increments of 0.5D
Optics design
Aspherical, non-aberrational (Unified optical power over the optical length of the lens)
Haptic tilt (A-constant)
0˚ (A-constant 118.0) or 5˚ (A-constant 118.2)
UV protection
Full UV protection (UV-A, UV-B, UV-C) 390 nm. or UV protection + yellow filter 430 nm.
Haptic shape
"Bi-haptics" (Double: external and internal with compensator)
Right angle
360˚ right angle around the lens + right angle at the junction of optics and haptics
Anti-glare technology
Special design of the optical part of the lens removes glare (Excludes dysphotopsia)
Lens delivery system
The lens comes with an injector and a cartridge of the Butterfly form (Butterfly)
Injector and cartridge
2.2 mm or 2.4 mm
CrystalView® LM-S
Intraocular lens with injector and cartridge

LM-S60S LM-S60M LM-S60L
Optics diameter
6.00 mm 6.00 mm 6.00 mm
Haptic diameter
12.00 mm 12.50 mm 12.50 mm
Material
Hydrophilic acrylic
Lens type
Posterior chamber
Diopter series
-15.0 D to -0.5 D in 0.5D increments from +0.5 D to +45.0 D in increments of 0.5D
Optics design
Aspherical, non-aberrational (Unified optical power over the optical length of the lens)
Haptic tilt (A-constant)
0˚ (A-constant 118.0) or 5˚ (A-constant 118.2)
UV protection
Full UV protection (UV-A, UV-B, UV-C) 390 nm. or UV protection + yellow filter 430 nm.
Haptic shape
S-loop (Haptic S-shaped)
Right angle
360˚ right angle around the lens + right angle at the junction of optics and haptics
Anti-glare technology
Special design of the optical part of the lens removes glare (Excludes dysphotopsia)
Lens delivery system
The lens comes with an injector and a cartridge of the Butterfly form (Butterfly)
Injector and cartridge
2.2 mm or 2.4 mm
CrystalView® LM-M105
Intraocular lens with injector and cartridge
Optics diameter
6.00 mm
Haptic diameter
10.50 mm
Material
Hydrophilic acrylic
Lens type
Posterior chamber
Diopter series
-15.0 D to -0.5 D in 0.5D increments from +0.5 D to +45.0 D in increments of 0.5D
Optics design
Aspherical, non-aberrational (Unified optical power over the optical length of the lens)
Haptic tilt (A-constant)
0˚ (A-constant 118.0) or 5˚ (A-constant 118.2)
UV protection
Full UV protection (UV-A, UV-B, UV-C) 390 nm. or UV protection + yellow filter 430 nm.
Haptic shape
M-model (Closed haptic with compensator)
Right angle
360˚ right angle around the lens + right angle at the junction of optics and haptics
Anti-glare technology
Special design of the optical part of the lens removes glare (Excludes dysphotopsia)
Lens delivery system
The lens comes with an injector and a cartridge of the Butterfly form (Butterfly)
Injector and cartridge
2.2 mm or 2.4 mm
CrystalView® LM-Q110
Intraocular lens with injector and cartridge
Optics diameter
6.00 mm
Haptic diameter
11 mm
Material
Hydrophilic acrylic
Lens type
Posterior chamber
Diopter series
-15.0 D to -0.5 D in 0.5D increments from +0.5 D to +45.0 D in increments of 0.5D
Optics design
Aspherical, non-aberrational (Unified optical power over the optical length of the lens)
Haptic tilt (A-constant)
0˚ (A-constant 118.0) or 5˚ (A-constant 118.2)
UV protection
Full UV protection (UV-A, UV-B, UV-C) 390 nm. or UV protection + yellow filter 430 nm.
Haptic shape
Closed haptic in the form of a trapezoid plate with rounded ends and perforations in the center.
Right angle
360˚ right angle around the lens + right angle at the junction of optics and haptics
Anti-glare technology
Special design of the optical part of the lens removes glare (Excludes dysphotopsia)
Lens delivery system
The lens comes with an injector and a cartridge of the Butterfly form (Butterfly)
Injector and cartridge
2.2 mm or 2.4 mm
CrystalView® LM-X105
Intraocular lens with injector and cartridge
Optics diameter
6.00 mm
Haptic diameter
10.50 mm
Material
Hydrophilic acrylic
Lens type
Posterior chamber
Diopter series
-15.0 D to -0.5 D in 0.5D increments from +0.5 D to +45.0 D in increments of 0.5D
Optics design
Aspherical, non-aberrational (Unified optical power over the optical length of the lens)
Haptic tilt (A-constant)
0˚ (A-constant 118.0) or 5˚ (A-constant 118.2)
UV protection
Full UV protection (UV-A, UV-B, UV-C) 390 nm. or UV protection + yellow filter 430 nm.
Haptic shape
X-loop (Four supporting haptic with perforation)
Right angle
360˚ right angle around the lens + right angle at the junction of optics and haptics
Anti-glare technology
Special design of the optical part of the lens removes glare (Excludes dysphotopsia)
Lens delivery system
The lens comes with an injector and a cartridge of the Butterfly form (Butterfly)
Injector and cartridge
2.2 mm or 2.4 mm
CrystalView® LM-H107
Intraocular lens with injector and cartridge
Optics diameter
6.00 mm
Haptic diameter
10.70 mm
Material
Hydrophilic acrylic
Lens type
Posterior chamber
Diopter series
-15.0 D to -0.5 D in 0.5D increments from +0.5 D to +45.0 D in increments of 0.5D
Optics design
Aspherical, non-aberrational (Unified optical power over the optical length of the lens)
Haptic tilt (A-constant)
0˚ (A-constant 118.0) or 5˚ (A-constant 118.2)
UV protection
Full UV protection (UV-A, UV-B, UV-C) 390 nm. or UV protection + yellow filter 430 nm.
Haptic shape
H-loop (Four supporting haptic)
Right angle
360˚ right angle around the lens + right angle at the junction of optics and haptics
Anti-glare technology
Special design of the optical part of the lens removes glare (Excludes dysphotopsia)
Lens delivery system
The lens comes with an injector and a cartridge of the Butterfly form (Butterfly)
Injector and cartridge
2.2 mm or 2.4 mm
ZooView® Q-110
Hydrophilic intraocular lenses for dogs and cats
Material
Hydrophilic acrylic with UV protection
Optical Diameter / Overall
6.00 mm / 11.00 mm
Haptic angle
0˚
Diopter
for dogs from +40.0 to +45.0 diopters
for cats +50.0 to 55.0 diopters
Sterilization method
Steam sterilization
360° right angle
360° right angle on optics and haptic
A constant
118
IOL-CHALLY®
Three-pieces, posterior chamber
Polymethilmetacrylate (PMMA)
With yellow filter
Optics diameter
5.00 mm
Haptic diameter
11.0 mm
Material
Polymethylmethacrylate and Nylon
Lens type
Posterior chamber, Three-pieces
Diopter series
7˚
Haptic tilt
360° right angle on optics and haptic
A constant
A-constant 118.6
UV protection
UV protection + yellow filter 430 nm.
Haptic shape
Closed support elements with compensator
IOL-S-CHALLY®
Three-pieces, posterior chamber
Polymethilmetacrylate (PMMA)
With yellow filter
Optics diameter
6.00 mm
Haptic diameter
13.0 mm
Material
Polymethylmethacrylate and Nylon
Lens type
Posterior chamber, Three-pieces
Diopter series
+1.0 D to +35.0 D in increments of 1.0 D
Haptic tilt
0˚
A constant
A-constant 118.0
UV protection
UV protection + yellow filter 430 nm.
Haptic shape
S-shaped haptic
IOL-CHALLY® T2
Single pieces IOL
Polymethilmetacrylate (PMMA)
Posterior chamber
Optics diameter
5.50 mm
Haptic diameter
12.5 mm
Material
Polymethylmethacrylate
Lens type
Posterior chamber, Single piece
Diopter series
+1.0 D to +35.0 D in increments of 0.5 D
Haptic tilt
5
A constant
A-constant 118.2
UV protection
Full UV protection (UV-A, UV-B, UV-C) 390 nm.
Haptic shape
S-shaped haptic with shock absorbing effect
IOL-CHALLY® T4
Single pieces IOL
Polymethilmetacrylate (PMMA)
Anterior chamber
Optics diameter
5.50 mm
Haptic diameter
12.5 mm
Material
Polymethylmethacrylate
Lens type
Anterior chamber, Single piece
Diopter series
+1.0 D to +35.0 D in increments of 0.5 D
Haptic tilt
0˚
A constant
A-constant 115.3
UV protection
Full UV protection (UV-A, UV-B, UV-C) 390 nm.
Haptic shape
Z-loop with shock absorbing effect
Eye prostheses polymeric
Polymeric individual single-and double-walled prostheses with various colors of the iris and sclera of PGP "Latan" are used for medical and cosmetic purposes for prosthetics of people who have one or both eyes, as well as in the presence of a remnant of an eyeball or an eyesore.

Dentures are made of polymer material recommended for use by the Committee on New Technology of the Ministry of Health of the Russian Federation (the product is certified and registered).

Dentures are resistant to mechanical stress, subject to restoration, comfortable to wear in cold and hot climatic zones, characterized by practicality, comfort, and durability.
Our advantages
Latan® - production of intraocular lenses in Russia
Our certificates

We are manufacturers!
Order products directly
from the manufacturer
Shipping in Africa & the Middle East
We will deliver the products to your destination of charge by the best transport company
Quality assurance
All our products are officially registered and certified.
Reviews
We have been implanting Latan intraocular lenses in our clinic for several years. The quality and commercial type of products is made at the level of elite European products, despite the fact that the price is 40% lower!
Fedorov M.V.
Director
Complex Cataract Center "Concor"
Quality control of our products. Track our products across the world. It is our responsibility.
Khachabi J.
General Director RUMA GROUPS
I personally implant Latan products in our clinic. Crystal View intraocular lenses can be easily implanted. Convenient delivery system. The quality of vision of patients is consistently higher than 0.75. There are no difficulties during implantation.
Ivonin K. S.
Doctor-Surgeon
"Kirov Regional Clinical Hospital"
We conducted clinical trials of Latan products. The quality of these products is worthy of respect. It is gratifying that lenses of this quality are produced in a Russian company known all over the world.
Trubilin V. N.
President of the Russian Society of Cataract and Refractive Surgeons
Logo
© 2023 Company Inc. All rights reserved.
  • About us
  • Industry Hi-Tech
  • Environment
  • Medical care
  • Education
  • Services
МОСКВА — ул. Театральная 48а
ЕКАТЕРИНБУРГ — ул. Вайнера 28
+7 (499) 123-45-67
INFO@MADETHOUGHT.COM
  • About us
  • Our projects
  • Our associations
  • Contacts